NUON Hemweg 8
Retrofit with Efficiency Increase of Flue Gas Desulphurization Plant (FGD), 680 MWel, 1980 t/h > Flue Gas Treatment
![](assets/images/0/steinmueller_engineering_references_projects_map_location_5_hemweg_8-b107d25e.jpg)
Legende
Ausgewählte Referenzen von Steinmüller Engineering
Erfolge
- SO2 removal efficiency increase from 92,9 % to 95,2 %
- Sulphur dioxide emission reduced by more than 30%
FGD Design:
- Diameter of scrubber: 18m
- Number of spray levels: 4
Umfang des Angebots
- Supply of new double hollow cone and full cone nozzles
- Nozzle installation based on Advanced Nozzle Positioning (ANP) Technology
- Refurbishment of piping system
- Further process optimization options identified and proposed in additional engineering study
weiterlesen
Nachrüstungen und
Prozessoptimierungen an
Rauchgasentschwefelungsanlagen
![](assets/images/b/DSC03693%20-%20Webseite-3d17e3d4.png)
Ansprechpartner
Dr.-Ing. Axel Thielmann
Business Development Manager
Telefon +49 2261 78950 145
Mobil +49 173 2724 648
Schreiben Sie eine E-Mail